Industry Solution

Municipal Water Supply

Drinking Water Treatment & Distribution Network Monitoring

Application Overview

Municipal water supply systems — from source water intake and treatment to distribution network management — require reliable instrumentation for regulatory compliance, public health protection, and operational efficiency. TL Environment provides metering pumps for disinfectant and coagulant dosing, online sensors for continuous water quality monitoring, and flowmeters for accurate billing and network leak detection.

Key Challenges

  • Maintaining disinfectant residual throughout the distribution network
  • Compliance with drinking water quality standards (WHO, EPA, EU Directive)
  • Accurate flow measurement for billing, water balance, and non-revenue water reduction
  • Turbidity monitoring at treatment plant outlets and network monitoring points
  • pH control for corrosion prevention in distribution infrastructure
  • Remote monitoring and SCADA integration for unattended operation

Key Monitoring Parameters

  • Free Chlorine (mg/L)
  • pH
  • Turbidity (NTU)
  • Conductivity / TDS
  • Flow Rate (m³/h)
  • Pressure (bar)

Need a Custom Solution?

Our engineers can design a complete instrumentation package for your specific process requirements.

Contact Engineering Team

Process & Instrumentation Overview

1
Source Water Intake

Flow measurement at intake; turbidity and conductivity monitoring of raw water quality.

2
Coagulation & Flocculation

Metering pumps dose coagulants based on raw water turbidity and flow rate.

3
Filtration

Turbidity sensors monitor filter outlet quality and trigger backwash cycles.

4
Disinfection

Metering pumps dose chlorine or NaOCl; chlorine sensors verify residual concentration.

5
Fluoridation (where required)

Metering pumps dose fluoride compounds at precise concentrations for dental health programs.

6
Distribution Network Monitoring

Chlorine, pH, and turbidity sensors at network monitoring points ensure water quality throughout distribution.

Chemical Dosing Points

Dosing LocationChemicalRecommended EquipmentPurpose
Raw Water InletPAC (Polyaluminum Chloride)Mechanical Diaphragm Metering Pump (HJ-W Series)Coagulation dosing proportional to raw water flow
Flocculation TankPAM (Polyacrylamide)PAM Preparation & Dosing SystemFlocculation aid for improved sedimentation
Pre-chlorination PointSodium Hypochlorite (NaOCl)Sodium Hypochlorite Dosing SystemPre-disinfection and algae control
Filtered Water ChannelNaOCl or ClO₂Solenoid Diaphragm Metering Pump (H+ Series)Final disinfection to achieve residual chlorine target
pH Correction PointCa(OH)₂ or NaOHpH Adjustment Dosing SystemStabilize pH and reduce pipe corrosion

Water Quality Monitoring Points

Raw Water Inlet
TurbiditypHFlow Rate

Turbidity Sensor + pH Sensor + Electromagnetic Flowmeter

Sedimentation Outlet
Turbidity

Online Turbidity Sensor (TL-TU Series)

Filter Outlet
TurbiditypH

Turbidity Sensor + pH Sensor

Disinfection Contact Tank
Free ChlorinepH

Chlorine Sensor + pH Sensor

Distribution Network
Residual ChlorinePressureFlow

Chlorine Sensor + Pressure Transmitter + Flowmeter

Typical System Configuration

#011× PAC Dosing System (flow-proportional, with day tank and agitator)
#021× PAM Preparation & Dosing System (auto-dissolving, 2-tank design)
#031× NaOCl Dosing System (pre-chlorination + post-chlorination)
#041× pH Adjustment Dosing System with pH sensor feedback
#053× Electromagnetic Flowmeters (raw water, filtered water, distribution)
#065× Online Water Quality Sensors (turbidity ×2, pH ×2, chlorine ×1)
#071× SCADA-compatible PLC Control System with Modbus TCP/IP

Information Required for Solution Design

To provide an accurate system recommendation, please prepare the following information before contacting our engineers:

1Design capacity (m³/d) and peak hourly flow (m³/h)
2Raw water quality: turbidity (NTU), pH, alkalinity, hardness, iron, manganese
3Treated water standard (GB 5749-2022 or WHO Guidelines)
4Coagulant type and target dosing rate (mg/L)
5Disinfection method and target residual chlorine (mg/L)
6Distribution network pressure and pipe material
7Control system preference: standalone controller or SCADA integration

Ready to discuss your project?

Send us your parameters and receive a tailored solution design within 24 hours.

Request Solution Design

Frequently Asked Questions

Ready to Specify Instrumentation for Your Municipal Water Supply Project?

Share your process parameters and our engineering team will recommend the most suitable products, provide datasheets, and prepare a quotation.