Optical SensorsTL-TUR Series

Turbidity Sensor

Turbidity Sensor — TL-TUR Series
Optical Sensors

Turbidity Sensor

TL-TUR Series

90° scattered light turbidity sensor per ISO 7027. Range 0–4000 NTU, IP68, RS485 output.

Request a Quote

Product Overview

The TL-TUR Series measures water turbidity using the 90° scattered light (nephelometric) method in accordance with ISO 7027. Wide measuring range covers drinking water, surface water, and industrial effluent applications. Anti-fouling wiper option available.

Working Principle

Optical sensors use light-based measurement principles that eliminate the need for consumable reagents or electrolytes. Fluorescence optical DO sensors excite a luminophore coating with blue LED light; the returned red fluorescence signal is inversely proportional to dissolved oxygen concentration. Turbidity sensors transmit near-infrared light through the sample and measure the scattered light at 90°; the scatter intensity is proportional to suspended solids concentration. These principles provide stable, drift-free measurements with minimal maintenance requirements.

Wiring & Signal Output

Power supply: 12–24 V DC (standard); 220 V AC with adapter
Primary output: RS485 Modbus RTU (address configurable 1–247)
Analog output: 4–20 mA (proportional to measured value)
Relay output: 2 × SPDT relay for alarm / dosing control
Communication: Modbus RTU function codes 03 / 06 / 16
Cable entry: M16 cable gland, IP68 submersible cable available

Technical Specifications

ParameterValue
Measurement Principle90° scattered light (ISO 7027)
Turbidity Range0–100 / 0–1000 / 0–4000 NTU
Accuracy±2–3% FS
Resolution0.01 NTU (low range)
Temperature Range0–50°C
Signal OutputRS485 Modbus RTU / 4-20mA
Power Supply12–24 VDC
ProtectionIP68
MaterialSS316L

Key Features

  • ISO 7027 compliant measurement method
  • Three range options for different applications
  • Optional automatic cleaning wiper
  • Suitable for continuous immersion

Typical Applications

Drinking water treatmentSurface water monitoringEffluent discharge monitoringFilter performance control

Frequently Asked Questions

What measurement principle does this turbidity sensor use?+

The TL-TUR Series uses 90° scatter infrared optical measurement (ISO 7027 compliant), providing stable readings that are not affected by ambient light or sample colour.

What is the measurement range?+

0–4000 NTU (standard range). High-range versions up to 10,000 NTU are available for wastewater and sludge applications.

Can this sensor measure TSS (total suspended solids)?+

Yes. The TL-TUR Series can be configured for TSS measurement in mg/L, with calibration curves for specific sludge types. Contact us for TSS-specific calibration.

What is the IP rating and installation method?+

IP68 protection rating. Suitable for submersion, flow-through, and insertion installation. The anti-fouling wiper option is recommended for continuous wastewater monitoring.

Is this sensor suitable for filter effluent monitoring?+

Yes. Turbidity monitoring of filter effluent is one of the primary applications. The sensor provides early warning of filter breakthrough and supports regulatory compliance reporting.

Need technical support or a custom specification?

Our team responds within one business day.

Send Inquiry